每次測定前,應(yīng)對測定系統(tǒng)進行檢驗。用直徑50mm、高徑比1:1的實心鋼柱代替試件裝入試件夾持器內(nèi),再接入滲透系數(shù)測定系統(tǒng)。先用材料試驗機加軸向載荷至約15kN,關(guān)閉二通閥1,打開二通閥2,開動無級調(diào)速高壓水泵,待壓力達到圍壓規(guī)定值(約12MPa)關(guān)閉二通閥2,打開二通閥1,待壓力達到滲水壓力規(guī)定值(約10MPa)時停泵(此時軸向載荷將隨圍壓和滲水壓力增加到約20kN),穩(wěn)定30min,當(dāng)系統(tǒng)無漏水現(xiàn)象(各壓力值不降)時,確認系統(tǒng)完好。 上一頁 [1] [2] [3] [4] [5] [6] [7] [8] [9] [10] [11] [12] [13] [14] [15] [16] [17] [18] [19] [20] [21] [22] [23] [24] [25] [26] [27] [28] [29] [30] [31] [32] [33] [34] [35] [36] [37] [38] [39] [40] [41] [42] [43] [44] 下一頁 |